Your furnace has received the request for high heat, and it runs correctly. If you notice LED off, there’s no request for high heat. Here are the High- heat state-green LED codes: Code- LED off
#AEM AIR FUEL RATIO GAUGE FLASHES ERROR CODE 3 TIMES CODE#
If the phasing and polarity are incorrect, the code nine flashes will inform you about the problem. Should too many flame dropouts occur, the furnace will get in a lockout, and an eight flashes code will appear. When there is no ignition, the lockout will occur, and the seven flashes code will inform you. The six flashes code informs that the pressure switch cycle is in a lockout. Code-4 flashesĭucane furnace 4 LED blinking lights to inform that the high limit switch is open. Code- 3 Flashesĭucane gas furnace three flashes code signals that rollout, aux limit switch are open or the fire pressure is low. If the pressure switch closed while the inducer was off, you would notice the Code 2 flashes.

When you notice 1 Flash on the control panel, the flame is present, whereas the gas valve is off. Your furnace is operating correctly, so you have nothing to worry about. If that’s what you notice, there is no power to control, or the control hardware defect has occurred. You still have to start somewhere, so here are the codes that your furnace could be flashing. The error codes are useful, helping you decide what’s wrong with your furnace, but checking the error codes is just the first step to take when troubleshooting your Ducane furnace. What are the most common error codes for your Ducane furnace? Clogged ductwork can press the blower speed to run fast, leading to overheating the furnace and malfunctioning. Dirty filters that require cleaning and replacement can affect the heating abilities of the furnace. The gas input can also be too low for your furnace, so the unit cannot provide enough heat. In such a case, the temperature is reached too fast before the entire house is warmed up. But it can go the other way again, with a furnace that is too big for your home. Improper size of the furnaceĪ furnace that is too small for your household won’t be able to warm the house. Replacing the whole valve system is a solution, but only the professionals have the knowledge and skills to do it. Damaged wiring connections or loose wiring could also affect the proper operation of the furnace. If it’s turned to the “On” position or if it’s opened, you have discovered to cause. When the gas doesn’t reach the primary burners, the primary valve could generate the problem.

Sometimes, you will solve the problem only by replacing the fuse on the fan timer board or the transformer. There should be no tripped circuit breaker, no blown a fuse, and no defective wiring either. Should you realize that the burners don’t ignite, the first step is to see if the furnace is connected to the power supply.
#AEM AIR FUEL RATIO GAUGE FLASHES ERROR CODE 3 TIMES MANUAL#
Check your Owner’s Manual for further investigation. It’s also essential to examine the HSI (Hot surface ignitor) it could be damaged.ĭon’t forget to see if something is clogging the pilot orifice or the control valve could malfunction. When you’re trying to turn on your Ducane furnace and realize that the pilot light doesn’t light, you should check if the primary valve is switched to the “On” position.

Here are the most common issues with your Ducane furnace: Pilot light Troubleshooting your Ducane furnace doesn’t have to be very difficult, especially if you’re meticulous about it. What are the most common problems with the Ducane furnaces?